BATTERY CHARGER MASTERVOLT MASS 24/25-2 CSI-DNV 40720266
- Designed for the most difficult conditions.
- Lightweight, stainless steel, anodised aluminium casing.
- Coating of internal components prevents damage from damp or condensation to ensure a longer lifespan.
- Insensitive to electromagnetic effects from other devices.
- Suitable for every type of battery, also charges entirely empty batteries.
- Delivered as standard with temperature sensor.
- Full power at temperatures of up to 45 ?C.
- Load capacities from 80 to 1000 Ah or more.
- Stable and ripple free 24 and 48 V power supply, even without batteries.
- The Current Control function prevents the breakdown of fuses when the voltage drops.
- Parallel switching possible using multiple battery chargers.
- Connections in accordance with CE, ABYC A-31 and IEC60945.
Nominal output voltage | 24 V |
Total Charge Current | 25 A at 28.5V |
Number of battery outlets | 2 |
Charge current second output | 3:00 AM |
Battery capacity range | 50-250 Ah |
Nominal input voltage | 230 V (180-265 V), 50/60 Hz |
Power supply mode | yes |
Display/read-out | LED display |
Dimensions, hxwxd
| 365 x 220 x 111 mm 14.4 x 8.7 x 4.4 inch |
Weight
| 3.5 kg 7.7 lb |
Technical Specifications
Charge voltage Bulk | 28.5 V |
Charge voltage Absorption | 28.5 V |
Absorption time | 4 hours |
Charge voltage Float (wet batteries) | 26.5 V |
Charge voltage Float (Gel/AGM batteries) | 27.6 V |
Temperature sensor | yes (included) |
DC voltage compensation | yes |
Power consumption (DC side) | < 1 mA |
Full load consumption (230 V AC) | 880 W |
Current Control function | yes, through MasterBus |
Power factor control | > 0.95 |
Temperature range (ambient temp.) | -25 °C to 80 °C, derating > 45 °C |
| -13 °F to 176 °F |
Cooling | vario fan |
Protection degree | IP23 |
Protections | over temperature, over load, short circuit, high/low battery voltage |
MasterBus compatible | yes |
Charger Status Interface (alarm contact) | yes |