PHASE THREE 24V MARINE BATTERY CHARGERS

PHASE THREE 24V MARINE BATTERY CHARGERS

Code: B2C-NEWM-BCPT24V
Please call us for additional information

“Smart” marine battery charging technology for 24 and 32 volt systems aboard, workboats, military vessels, commercial vessels, and recreational craft. These chargers interact with batteries providing the optimum three stage charge process for fast recovery and conditioning, maximizing performance and extending battery life.

A selector switch adjusts output voltage to adapt to gel-cell/flooded lead-acid/AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. All models are housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.

 

Features

 

  • “Smart” circuitry provides three stage charging – bulk, absorption, float
  • Gel-Cell/Flooded Lead-acid/AGM battery type switch selects optimum charge/float voltages
  • Multiple isolated output banks; ammeter indicates total output current.
  • Optional sensor adjusts output voltage based on battery temperature.
  • Current limiting-prevents damage from overloading
  • Clean well regulated output can be used as a power supply; can power loads directly without a battery in line
  • Built to last – rugged stainless steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry
  • Protection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield
  • ABS type approval for battery charging and power supplies

 

 

Specifications

 

24 Volt Models

PT-24-8W

PT-24-13W

PT-24-20U

PT-24-45U

PT-24-60W

PT-24-95U

32 Volt Model
PT-32-25W

Input VAC (50-60 Hz.)

85 – 264

90 – 132
180 – 264

85 – 135
170 – 270

90 – 264

207 – 253

90-264

104-126

Input Amps @ F.L.
@ 115/ 230 VAC

2.8/1.4

6.5/4

6.8/4.3

12/7

NA/13

26/14

15/NA

Power Factor

.98@115V
.93@230V

.7

.7

.98@115V
.95@230V

.7

.98@115V
.95@230V

.7

Max Output Amps

8

13

20

45

60

95

25

Output Banks

3

3

3

3

3

3

3

Battery Capacity
(Amp-Hours)

16 – 80

26 – 130

40 – 200

90 – 450

120 – 600

180 – 950

50-250

Operating Temp.

T-1

T-2

T-3

T-5

T-4

T-5

T-4

Case Size Ref.

A- 1

A- 1

A- 2

A- 4

A- 5

A- 5

A- 3

Weight; Lbs./Kg.

8/4

8/4

12/6

12/6

24.1/11

24.5/11

12.2/6

Sensor Model

TCS-12/24

TCS-12/24

TCS-12/24

TCS-12/24

TP

TCS-12/24

TP

Remote Panel Model

RP

RP

N/A

RP

N/A

RP

N/A

Compliance Ref.

CG, CE,
ABS

CG, CE

CG, CE,
ABS

EN, CE,
ABS

EN, CE,
ABS

EN, CE,
ABS

EN, CE

 

 

Temperature Rating References

 

 

Temperature

Derate Linearly From

T-1

-10v C to +60˚ C

100% @ 40˚ C to 60% @ 60˚ C

T-2

-10v C to +60˚ C

100% @ 50˚ C to 60% @ 60˚ C

T-3

-20˚ C to +60˚ C

@ 50˚ to 60% @ 60˚ C

T-4

-20˚ C to +60˚ C

Full output

T-7

-20˚ C to +70˚ C

100% @ 50˚ C to 50% @ 70˚ C

 

 

Case Size References

 

Ref

Inches

 

 

Centimeters

 

 

 

H*

W

D*

H*

W

D*

A-1

11.2A

7.7

4.75A

31.8A

19.6

12.1A

A-2

13.85B

9.5

4.8B

35.2B

24.1

12.2B

A-3

13.8C

9.8

5C

35C

24.9

12.7C

A-4

14.8D

9.6

5.6D

37.6D

24.4

14.2D

A-5

17.5E

12

7.2E

44.5E

30.5

18.3E

*With Dripshield Installed:
A Add 1.1″ (2.8 cm) to height and .92″ (2.3 cm) to depth
B Add .75″ (1.9 cm) to height and 1.35″ (3.4 cm) to depth
C Add 1.27″ (3.2 cm) to height and 1.1″ (2.8 cm) to depth
D Add 1″; (2.54 cm) to height and .5″ (1.27 cm) to depth
E Add 2″ (5.08 cm) to height and 1″ (2.54 cm) to depth 

 

 

Compliance References

 

UL: UL 1950 (per DNB report)
CG: USCG CFR 183.410 (Ignition protected)
EN: EN 60335-1
CE: Carries the CE mark
ABS: PT Series meet SVR 2009 4-8-3/5.9, Under 90 meters Rules 2006 4-6-4/7.19, and HSNC 2007 4-8-3/5.13.

 

 

Nominal Output Voltages at Gel/Flooded Switch Settings
(without Temperature Compensation)

 

 

Setting

Charge @ 50% load

Float @ .5 amp load

24 Volt Models

 

 

Gel-Cell

25.0 VDC

27.2 VDC

Flooded/AGM

28.4 VDC

26.8 VDC

32 Volt Model

 

 

Gel-Cell

37.3 VDC

36.2 VDC

Flooded/AGM

37.8 VDC

35.7 VDC

 

 

 

Options

 

Remote Panel, model RP, for use with all models except PT-24-20U, PT-24-60 and PT-32-25
LED’s indicate charger output stage. Manual re-initialization of three stage charge cycle. With 25′ of cable. Panel dimensions: 3″ H x 4.75″ W.