BATTERY CHARGERSBC2450 NRG+ 24V 100A 3OUT
- Three stage IUoU battery charging.
- High efficiency.
- Multiple outputs in order to charge more groups of batteries (Electronic mosfet charge separator inside).
- Differentiated charging for open or sealed liquid electrolite, gel, AGM, Optima®, Li-Ion. batteries.
- Integrated output fuses inside the battery charger (for each output).
- Capacity of supplying full power with low AC network supply voltage.
- Low residual fluctuation on output.
- Universal AC supply input (HR models escluded).
- Power factor (cos ?) equal to 1.
- Compatible with the generators.
- Can work in a wide range of ambient temperatures.
- Variable speed for the cooling fan.
- User interface via LEDs that signal the status, errors and the output current.
- Automatic and manual power derating (via CAN bus).
- CAN bus interface for data transfer.
- Possibility to connect up to three battery chargers of the same model in parallel, by means of digital control, for current sharing.
- Charge is compensated according to the temperature of the batteries (1 sensor supplied; more sensors optional).
- Thermal battery protection (with optional sensors).
- Short circuit, overloading, output overvoltage and overheating protection
Specifications
Max output current | 100 A |
Charge absorption voltage
| 28.2 Vdc OL • 28.4 Vdc Li-Ion 28.8 Vdc SL/GEL/AGM • 29.4 Vdc Optima |
Charge float voltage
| 26.8 Vdc OL • 27.0 Vdc Li-Ion • 27.2 Vdc AGM 27.6 Vdc SL/GEL/Optima |
Number of outputs | 3 |
Supply voltage | 264÷83 Vac, linear reduction to 108 Vac |
Frequency | 45 ÷ 66 Hz |
Efficiency | ≥ 92% |
Max absorption (230/240 Vac) | 12.5 A |
Max absorption (120 Vac) | - |
Operating temperature | +5°F ÷ +158°F, with linear power reduction over +122°F |
Cooling | Forced, by variable speed cooling fans |
Dimensions W x H x D
| 170 x 481 x 82 mm 6"11/16 x 18"15/16 x 3"15/64 |
Weight
| 3,1 Kg 9.3 lb |
Dimensions